Ewshear Configuration File
(last revised 31 October, 2011)
#
# ewshear Configuration File
#
MyModuleId MOD_EWSHEAR # module id for this program
InRing TEST_RING # transport ring to use for input
OutRing HYPO_RING # transport ring to use for output
HeartBeatInt 30 # EW internal heartbeat interval (sec)
LogFile 1 # If 0, don't write logfile
# if 1, do (DEFAULT)
# if 2, write to module log but not to
# stderr/stdout
MaxMsgSize 4096 # maximum size (bytes) for input/output msgs
#
# Floor definitions -- exactly one of each kind
# Each specifies the SCNL for that Floor's sensor
#
GroundFloor 5405 HNE NP ES
TopFloor 5405 HNE NP GS
#
# Vertical distance between floors
#
Height 100
#
# Length of sampling window (seconds)
#
WindowSize 5
#
# Optional override of threshold for alarm
#
# PctShearThreshold 25 # % change in velocity to trigger alarm; default is 20
#
# Epsilon used in computing cross-correlation
# Default is 0
# Epsilon
# Taper source data: Type Fraction
# Type is either BARTLETT, HANNING, PARZAN, or BMHARRIS
# Fraction is how much of each end of data is tapered
Taper HANNING 0.1